- Description
- Product Brochure
- Inquiry
High and Low Temperature Tensile Testing Machine with Environmental Test Chamber
Computer Control Electromechanical Universal Testing Machine
(load capacity 50kN, 100kN)
1. Introduction
This environmental test chamber is used for low and high temperature test of metal materials and non-metal materials, composite material, etc, the temperature range can be made according to the customer’s requirement. For example, -20℃~+150℃. By menas of relative test accessory, it can do tensile, compression, bending test.
2. System composed
This stem is compsed of chamber body, temperature control and measure display system, heating system, cooling system, temperature measure component, wind cycling system, adjustable mobile trolley, etc
3. Specifications of Environmental Test Chamber
Temperature range: -20℃~ 150℃
Temperature measuring sensitivity: 0.1℃
Temperature measuring accuracy: ±1℃
Chamber inside work room size: 400mm×500mm×500mm (W×D×H)
Chamber outsize size: 600mm×700mm×600mm (W×D×H)
Insulation material thickness: >80mm
4. Specifications of Testing Machine
Model | WDW-50 |
Host Machine Structure | double space |
Max Load Capacity (kN) | 50 |
Class of Machine | 0.5 |
Load Range | 0.4%-100% FS |
Load Accuracy | Within ±0.5% of indicating value |
Load Resolution | 1/300000 |
Range of Deformation | 4%-100%FS |
Resolution of Deformation (mm) | 0.001 |
Accuracy of Displacement | Within ±0.5% of indicating value |
Resolution of Displacement (mm) | 0.01 |
Range of Testing Speed (mm/min) | 0.01- 500 |
Max Tensile Space (mm) | 1000 |
Max Compression Space (mm) | 1100 |
Clearance between columns (mm) | 600 |
Working Environment | Room temperature 10℃~30℃,
relative humidity≤80% |
Total Power Supply | 1-phase, 220V±10%, 50Hz |
Host Machine Dimension (mm) | 900×520×2450 |
Net Weight (kg) | 800 |
It is customizde made testing machine, please feel free to contact us.
Our email is sales@victorytest.com