ISO148 Charpy Impact Testing Machine
ISO148 Metallic materials- Charpy pendulum impact test- Part 1: Test method
Control mode: computer control, touch screen meter control
Display mode: computer, touch screen meter, dial
Impact energy: 300J, 450J, 600J, 750J
Test standard: it also conforms to ASTM E23
- Description
- Inquiry
ISO148 Charpy Impact Testing Machine
JBW-C Series Computerized Charpy Impact Testing Machine
(New product, computer control + LCD control, 300J, 450J, 600J, 750J, full protect cover)
Application & Features:
JBW-C series Computer Display Pendulum Impact Testing Machine are newly designed full protect cover to protect the operator’s safety, it is mainly used to determine the anti-impact capability of metal materials under dynamic load. Carry out the functions of zero clearing and automatic return, capturing the value of lost impact energy and pendulum cycle by means of setting up with computer program, and the results can be monitored, stored and printed out. It supports both computer control and LCD control.
Standards:
ASTM E23, ISO148-2006 and GB/T3038-2002, GB/229-2007.
Main Technical Specifications:
Specifications | JBW-300C | JBW-450C | JBW-600C | JBW-750C |
Max. impact energy (J) | 300 | 450 | 600 | 750 |
Effective use of scope | 20% -80% F.S | |||
Pendulum weight (N) | 214.3594 | 321.5391 | 428.7188 | 535.8985 |
Moment of pendulum (N.m) | 160.7696 | 241.1543 | 321.5391 | 401.9239 |
Impact velocity (m/s) | 5.24 | |||
Raised angle | 150º | |||
Standard span (mm) | 40 | |||
Distance between pendulum rotating center and specimen center (mm) | 750 | |||
Round angle of jaws (mm) | R1-1.5 | |||
Round angle of striking edge (mm) | R2-2.5 (R8 is optional) | |||
Size of specimen (mm) | 10x10x55, 10×7.5×55, 10x5x55, 10×2.5×55 | |||
Angle measuring method | Photoelectric encoder | |||
Accuracy of angle measuring | 0.06º | |||
Digital display angle resolution | 0.015º | |||
Digital display reading resolution (J) | 0.12 | |||
Impact energy display method | Dial, LCD and computer | |||
Dial minimum resolution | ≥0.5J | ≥0.75J | ≥1J | ≥1.25J |
Dimension of host machine (mm) | 2220 x 900 x 2220 (install protect cover) | |||
Dimension of electric cabinet (mm) | 960 x620 x830 | |||
N.W of host machine (kg) | 1500 | |||
N.W of electric cabinet (kg) | 100 | |||
Power supply | 3- ph, 380V, 50Hz | |||
Power of electric motor (kW) | 1.5 | |||
Working environment | Non-vibration, non-dusting, room temperature 15-25℃, humidity <70% |
For more detailed info, please contact us by email: sales@victorytest.com